Answers for buyers comparing the SS304 treadle eye wash station’s construction, operation, installation conditions, pressure, flow, maintenance, and ordering details for industrial and laboratory sites.
The SS304 treadle eye wash station provides emergency eye and face washing for laboratories and industrial sites. It uses a hands-free treadle to start the water flow, so an operator can activate the unit without using contaminated hands. The bowl has a 300 mm straight edge designed to help prevent splashing.
For product details, see the SS304 treadle eye wash station.
The station is made from SS304 stainless steel. Buyers can specify a polished or glossy epoxy-coated finish. This construction suits industrial and laboratory settings where the unit may be exposed to moisture or chemical work areas.
Press the treadle to open the eye wash. The unit uses a two-piece ball valve and is designed for hands-free activation. Integrated dust covers remain attached to the spray heads and protect them from contaminants when the station is not in use.
A practical installation check is to place the station where a worker can reach it within 10 seconds, approximately 55 feet, of a potential chemical hazard area. Keep the route clear so the treadle can be reached quickly.
The rated water flow is at least 11.4 L/min. The nominal pressure is 1.0 MPa, the working pressure is 0.2 to 0.4 MPa, and the test pressure is 1.5 MPa. The working temperature range is 0°C to 40°C.
Before ordering, send the facility’s inlet pressure, water temperature range, and plumbing layout to the supplier so the connection can be checked against the station requirements.
The station has an anti-freezing drainage design that automatically drains the pipeline after use. This helps address water stagnation and freezing concerns in cold-climate installations. The stated working temperature range is 0°C to 40°C, so buyers should match the installation environment to that range.
A weekly inspection should activate the valves, check water flow, and verify pressure. Inspect the spray heads regularly for clogs and remove impurities from the dust covers. A monthly maintenance routine should fully drain the pipes to remove sediment and help prevent bacterial growth.
For a self-contained unit, check water clarity and replace the stored water as part of the water-quality check. The treadle should also be operated to confirm smooth mechanical movement.
Send the required quantity, installation location, inlet and outlet arrangement, finish preference, water pressure, operating temperature, and facility plumbing layout. The station supports customizable inlet and outlet configurations, so these details help the supplier review the intended installation before preparing a quotation.
The company
Hebei Runwangda Laboratory Equipment Co., Ltd. was established in 1982, with a headquarters area exceeding 26,000 square meters, over 150 employees, and a warehouse area of more than 2,000 square meters. The company focuses on the research and development (R&D) and production of laboratory faucets, gas valves, fume extractors, PP pegboard, PP sinks, emergency showers, and eye wash station, which are widely used in education, scientific research, pharmaceuticals, chemical engineering, petrochemicals, electronics,…
About Us ↗Visit company website ↗Your next step
Use case, specification, quantity and delivery window: make the next conversation specific.